Becker and Hickl products include photon counters, time correlated single photon counting (TCSPC) cards, detectors, sampling modules, diode lasers, lock-in amplifiers, delay generators and amplifiers. These systems are integrated into fluorescence systems and laser scanning microscopes for fluorescence resonance energy transfer (FRET) and fluorescence lifetime imaging (FLIM).
Becker and Hickl develop and manufacture innovative control and measurement systems and complete time correlated single photon counting (TCSPC) systems. No other manufacturer of TCSPC systems displays both cutting edge speed and detectability along with a unique abilty to customise systems specifically around your photon counting requirements.
Pulsed and continuous wave diode laser with wavelengths from 375 to 785nm, power from 40 to 500mW, repetition rate from 20 to 80MHz and pulsewidth from 40 to 300ps.
Becker and Hickl's (B&H) DCS-120 confocal scanning fluorescence lifetime imaging (FLIM) system is a complete confocal laser scanning microscope for FLIM. The system uses B&H’s multidimensional time correlated single photon counting (TCSPC) FLIM technology in combination with laser scanning and confocal detection.
The LINCam system grants single photon acquisition in a wide-field photon counting mode. The core of the system is a position sensitive photomultiplier tube (PMT) based on microchannel plates (MCPs) with a multialkali photocathode.
The Becker and Hickl DCS-120 MACRO scanner can now be combined with Becker and Hickl's FASTAC fast acquisition FLIM system.
The PHDIS-04 photon spinner from Becker and Hickl enables the connection of one detector, e.g. HPM-100 series high speed hybrid detector, with four SPC-150N time correlated single photon counting (TCSPC) fluorescence lifetime imaging (FLIM) modules.
The Becker and Hickl (B&H) fast acquisition fluorescence lifetime imaging (FLIM) system is based on the multidimensional time correlated single photon counting (TCSPC) technique.
Upgrade your Zeiss 710, 780 and 880 laser scanning microscopes to carry out fluorescence lifetime imaging (FLIM) with these highly modular systems from Becker and Hickl.
Upgrade your laser scanning microscope to carry out fluorescence lifetime imaging (FLIM) with these highly modular systems from Becker and Hickl. Available for multiphoton non-descanned detection (NDD), FLIM confocal, upright and inverted microscopes.
The Becker and Hickl (B&H) multiwavelength fluorescence lifetime imaging (FLIM) system is designed as an upgrade to laser scanning microscopes. It is an excellent choice for tissue autofluorescence imaging, combined FLIM, second harmonic generation (SHG) imaging, and fluorescence resonance energy transfer (FRET) experiments.
Becker and Hickl's range of fluorescence lifetime imaging (FLIM) systems is expanded with the introduction of a non-descanned detection (NDD) unit for use with Leica SP2 and SP5 multiphoton microscopes.
The SPC-150NX single photon counting card from Becker and Hickl (B&H) is the highest resolution time correlated single photon counting (TCSPC) card available, offering unsurpassed electrical timing resolution down to 3.3ps full width at half maximum (FWHM) / 1.6ps root mean square (RMS).
The SPC-150N time correlated single photon counting (TCSPC) fluorescence lifetime imaging (FLIM) module from Becker and Hickl (B&H) is a TCSPC imaging and fluorescence correlation spectroscopy (FCS) module for laser scanning microscopes.
The SPC-160PCIE time correlated single photon counting (TCSPC) fluorescence lifetime imaging (FLIM) module from Becker and Hickl (B&H) features a peripheral component interconnect express (PCIE) interface. This module offers high end performance TCSPC and multiscalar imaging and fluorescence correlation spectroscopy (FCS) for laser scanning microscopes.
The SPC-160 time correlated single photon counting (TCSPC) fluorescence lifetime imaging (FLIM) module from Becker and Hickl (B&H) offers high end performance TCSPC and multiscalar imaging and fluorescence correlation spectroscopy (FCS) module for laser scanning microscopes.
The SPC-150NXX single photon counting card from Becker and Hickl (B&H) is the Extreme-Resolution Version of the SPC-150N, offering the highest resolution time correlated single photon counting (TCSPC) with unsurpassed electrical timing resolution down to 3ps (FWHM) / 1.1ps (RMS).
Pulsed and continuous wave diode laser with wavelengths from 532 to 594nm, power from 0.3 to 0.5mW, repetition rate from 20 to 50MHz and a pulsewidth of 50ps.
Pulsed diode laser with wavelengths from 405 to 915nm, power from 10 to 60mW, repetition rate from 20 to 50MHz and pulsewidth from 65 to 300ps.
Pulsed and continuous wave diode laser with wavelengths from 375 to 1064nm, power from 1 to 50mW, repetition rate from 20 to 50MHz and pulsewidth from 30 to 300ps.
The SPC-150NX single photon counting card from Becker and Hickl (B&H) is the highest resolution time correlated single photon counting (TCSPC) card available, offering unsurpassed electrical timing resolution down to 3.3ps full width at half maximum (FWHM) / 1.6ps root mean square (RMS).
The SPC-150N time correlated single photon counting (TCSPC) fluorescence lifetime imaging (FLIM) module from Becker and Hickl (B&H) is a TCSPC imaging and fluorescence correlation spectroscopy (FCS) module for laser scanning microscopes.
The SPC-160PCIE time correlated single photon counting (TCSPC) fluorescence lifetime imaging (FLIM) module from Becker and Hickl (B&H) features a peripheral component interconnect express (PCIE) interface. This module offers high end performance TCSPC and multiscalar imaging and fluorescence correlation spectroscopy (FCS) for laser scanning microscopes.
The SPC-160 time correlated single photon counting (TCSPC) fluorescence lifetime imaging (FLIM) module from Becker and Hickl (B&H) offers high end performance TCSPC and multiscalar imaging and fluorescence correlation spectroscopy (FCS) module for laser scanning microscopes.
The SPC-830 time correlated single photon counting (TCSPC) fluorescence lifetime imaging (FLIM) module from Becker and Hickl features 1-4096 bins, 4k-16M blocks, 14 bit routing, scanning burst integrated fluorescence lifetime (BIFL) and operating software for Windows 95/98/NT/2k.
The SPC-150NXX single photon counting card from Becker and Hickl (B&H) is Extreme-Resolution Version of SPC-150N, offering the highest resolution time correlated single photon counting (TCSPC) and unsurpassed electrical timing resolution down to 3ps full width at half maximum (FWHM) / 1.1ps root mean square (RMS).
The DPC-230 16 channel photon correlator from Becker and Hickl (B&H) enables fluorescence correlation down to the picosecond range. This card is ideally suited to not just fluorescence correlation experiments, but also antibunching experiments and luminescence lifetime measurements.
Becker and Hickl's PML-Spec is ideal for visible wavelength high resolution (180ps) measurements. The PML-Spec has a 16 channel multispectral detection assembly to simultaneously record 16 wavelength channels for fluorescence decay functions.
The SPC-130-EMN time correlated single photon counting (TCSPC) module from Becker and Hickl (B&H) is the ideal entry level TCSPC card for basic TCSPC lifetime measurements.
Becker and Hickl's PMS-400A is a peripheral component interconnect (PCI) based two channel 800MHz gated multiscaler for photon counting and includes Windows compatible operating software.
The SPC-150N time correlated single photon counting (TCSPC) fluorescence lifetime imaging (FLIM) module from Becker and Hickl (B&H) is a TCSPC imaging and fluorescence correlation spectroscopy (FCS) module for laser scanning microscopes.
The SPC-160PCIE time correlated single photon counting (TCSPC) fluorescence lifetime imaging (FLIM) module from Becker and Hickl (B&H) features a peripheral component interconnect express (PCIE) interface. This module offers high end performance TCSPC and multiscalar imaging and fluorescence correlation spectroscopy (FCS) for laser scanning microscopes.
The SPC-160 time correlated single photon counting (TCSPC) fluorescence lifetime imaging (FLIM) module from Becker and Hickl (B&H) offers high end performance TCSPC and multiscalar imaging and fluorescence correlation spectroscopy (FCS) module for laser scanning microscopes.
The SPC-830 time correlated single photon counting (TCSPC) fluorescence lifetime imaging (FLIM) module from Becker and Hickl features 1-4096 bins, 4k-16M blocks, 14 bit routing, scanning burst integrated fluorescence lifetime (BIFL) and operating software for Windows 95/98/NT/2k.
The SPC-150NX single photon counting card from Becker and Hickl (B&H) is the highest resolution time correlated single photon counting (TCSPC) card available, offering unsurpassed electrical timing resolution down to 3.3ps full width at half maximum (FWHM) / 1.6ps root mean square (RMS).
Becker and Hickl's (B&H) DCS-120 confocal scanning fluorescence lifetime imaging (FLIM) system is a complete confocal laser scanning microscope for FLIM. The system uses B&H’s multidimensional time correlated single photon counting (TCSPC) FLIM technology in combination with laser scanning and confocal detection.
The SPC-150NXX single photon counting card from Becker and Hickl (B&H) is the Extreme-Resolution Version of the SPC-150N, offering the highest resolution time correlated single photon counting (TCSPC) with unsurpassed electrical timing resolution down to 3ps (FWHM) / 1.1ps (RMS).
The Becker and Hickl DCS-120 MACRO scanner can now be combined with Becker and Hickl's FASTAC fast acquisition FLIM system.
The DPC-230 16 channel photon correlator from Becker and Hickl (B&H) enables fluorescence correlation down to the picosecond range. This card is ideally suited to not just fluorescence correlation experiments, but also antibunching experiments and luminescence lifetime measurements.
Becker and Hickl's PML-Spec is ideal for visible wavelength high resolution (180ps) measurements. The PML-Spec has a 16 channel multispectral detection assembly to simultaneously record 16 wavelength channels for fluorescence decay functions.
The PHDIS-04 photon spinner from Becker and Hickl enables the connection of one detector, e.g. HPM-100 series high speed hybrid detector, with four SPC-150N time correlated single photon counting (TCSPC) fluorescence lifetime imaging (FLIM) modules.
The Becker and Hickl (B&H) fast acquisition fluorescence lifetime imaging (FLIM) system is based on the multidimensional time correlated single photon counting (TCSPC) technique.
Upgrade your laser scanning microscope to carry out fluorescence lifetime imaging (FLIM) with these highly modular systems from Becker and Hickl. Available for multiphoton non-descanned detection (NDD), FLIM confocal, upright and inverted microscopes.
The Becker and Hickl (B&H) wide field fluorescence lifetime imaging (FLIM) system is based on the multidimensional time correlated single photon counting (TCSPC) technique.
Upgrade your Zeiss 710, 780 and 880 laser scanning microscopes to carry out fluorescence lifetime imaging (FLIM) with these highly modular systems from Becker and Hickl.
The Becker and Hickl (B&H) multiwavelength fluorescence lifetime imaging (FLIM) system is designed as an upgrade to laser scanning microscopes. It is an excellent choice for tissue autofluorescence imaging, combined FLIM, second harmonic generation (SHG) imaging, and fluorescence resonance energy transfer (FRET) experiments.
Becker and Hickl's range of fluorescence lifetime imaging (FLIM) systems is expanded with the introduction of a non-descanned detection (NDD) unit for use with Leica SP2 and SP5 multiphoton microscopes.
The SPC-130-EMN time correlated single photon counting (TCSPC) module from Becker and Hickl (B&H) is the ideal entry level TCSPC card for basic TCSPC lifetime measurements.
Becker & Hickl's family of Simple-Tau systems feature full control and acquisition systems for a complete tabletop standalone time correlated single photon counting (TCSPC) system. Systems are available based on the SPC-830, SPC-130-EMN or SPC-150N and are available in single, dual or four channel format.
Use the HRT-41 from Becker and Hickl to connect to up to 4 photomultiplier tube (PMT) time correlated single photon counting (TCSPC) detectors to one controller.
The HRT-81 module from Becker and Hickl connects up to eight separate detectors to one TCSPC module.
Becker and Hickl's HRT-82 time correlated single photon counting (TCSPC) router module for avalanche photodiodes (APDs) connects up to eight separate APD modules to one TCSPC module.
The DDG-210 digital pulse/delay generator from Becker and Hickl has 2 synchronous reference outputs and 6 delayed output channels.
The DCC-100 detector control module from Becker and Hickl is for control of Becker and Hickl photomultiplier tube (PMT) modules.
The ACA series of gigahertz (GHz) wide band amplifiers have cut-off frequency of 2.2GHz and gain from 13dB to 37dB.
The HFAC-26 is a 5kHz to 1.6GHz wide band 26dB amplifier with overload detection for photomultiplier tubes (PMTs) or multichannel plates (MCPs).
The HFAH series of wide band 20dB or 40dB gigahertz (GHz) amplifiers are used to amplify the output signals from high speed photomultiplier tubes (PMTs) and multichannel plates (MCPs) for single photon counting applications at 500kHz to 430MHz.
PMC-150 from Becker & Hickl is a cooled high speed PMT detector head for photon counting. Ideal for TCSPC systems operated with DCC-100.
PML-16 from Becker & Hickl is a 16 channel photomultiplier head for bh Time Correlated Single Photon Counting (TCSPC) modules.
The HPM-100 series of high speed hybrid detectors for time correlated single photon counting (TCSPC) measurements from Becker and Hickl is available with either a gallium arseninde phosphide (GaAsP) cathode or a gallium arsenide (GaAs) cathode for increased near infrared sensitivity and an instrument response function of less than 20ps with clean response, no tails or secondary peaks and low afterpulsing probability.
The APM-400 from Becker & Hickl is a high speed avalanche photodiode module used for the detection of pulsed light signals and for trigger applications.
PDM-400 High speed PIN photo-diode from Becker & Hickl is used for the detection of light signals and for trigger applications.
The PHD-400 is a high speed, PIN photodiode module with current indicator. Suitable for high repetition rate TCSPC measurements.
High sensitivity integrating detector from Becker & Hickl for pulsed light signals. The PDI-400 includes a high performance photodiode, a low noise charge sensitive amplifier and an active high pass filter.